Skip to content

API reference ​

The API reference is organized as a set of short pages, following the same separation used by established Julia MRI documentation: each page focuses on one public type, constructor, or closely related function family. Scientific derivations and validation requirements remain in the Theory and Guide sections.

julia
HighOrderMRI

Field-aware MRI encoding, reconstruction and preprocessing. The module re-exports MRIGeometry and provides explicit and low-rank encoding operators. Input shapes, phase conventions and backend restrictions are documented at each interface.

Source: src/HighOrderMRI.jl

Encoding model and operators ​

  • Grid and basisfunc_spha: physical reconstruction grid and real solid-harmonic basis evaluation.
  • HighOrderOp: array-based explicit field-aware encoding.
  • HighOrderKernelOp: legacy/direct CUDA kernels and resident blocked/cached cuBLAS, with gpus selecting single- or multi-GPU execution.
  • explicit_gpu_normal: resident weighted normal from raw square-root weights; distinct from normalOperator(op,D) with an already squared diagonal.
  • HighOrderLowRankOp: low-rank residual-phase representation with shared or independent per-readout factors, including bounded streaming/regeneration and rank-sharded multi-GPU execution.

Reconstruction ​

  • recon_HOOp: iterative reconstruction wrapper, raw sample-weight convention, CPU/CUDA input requirements, and backend cleanup.

  • samplingDensity: square-root sampling-density weights for non-Cartesian reconstruction.

  • CoilCombineSOS: root-sum-of-squares combination along the selected coil dimension.

Coil compression ​

Field prediction and synchronization ​

  • GIRFModel: typed frequency-domain GIRF representation.
  • apply_girf: predict realized field channels from nominal physical gradients.
  • InterpTrajTime: interpolate field/trajectory coefficients to requested ADC times.
  • FindDelay: single-acquisition model-based field/data synchronization.
  • FindDelay_multishot: shared-delay estimation for multi-shot data.

Geometry ​

  • MRIGeometry: physical coordinates, slab handling, resampling and NIfTI export, including current restrictions.

Metrics and utilities ​

Reference vs. methods

Use these pages to check calling conventions and returned objects. Use Symbols and notation, the expanded encoding model, low-rank shared subspace, and the relevant Guide page when interpreting units, phase conventions, approximation parameters, or validation requirements.

HighOrderMRI.jl documentation · v0.1.1 · code 5d6ac72 · docs 5d6ac72