Skip to content

References ​

This page collects the literature cited throughout the documentation. Use the topic index to choose a starting point, then follow the linked guide for the package's equations, assumptions, and implementation choices. Constructor arguments and defaults are listed in the API reference.

Reading by topic ​

TopicStarting referencesPackage guide
Higher-order encoding and singular-vector separation1, 2, 3Encoding model
Randomized low-rank approximation and truncated SVD4, 5, 21Low-rank shared subspace
Parallel factorization and shared-subspace foundations22, 23Low-rank shared subspace
Snapshot POD, gappy fitting and QR point selection25, 26, 16, 17Direct Shared (Global strategy)
Phase-aware covering and global residual certification27, 29Selection and audit
Spectral truncation and MRI separable approximations5, 28, 30Error budget and related work
Field monitoring and gradient impulse responses6, 7Field preprocessing and synchronization
Field/data synchronization and related trajectory-correction methods8, 9, 10, 11Field preprocessing and synchronization
Receive-channel compression and noise weighting12, 13, 14, 15Coil compression
Explicit phase storage and GPU reconstruction24Relation to the non-Fourier SENSE preprint

Entries 2 and 14 identify published errata; consult those corrections when using the papers. Reference 24 links to the cited preprint version.

Bibliography ​

Reference numbers and ref-N anchors are shared across the site.

  1. Wilm BJ, Barmet C, Pavan M, Pruessmann KP. Higher order reconstruction for MRI in the presence of spatiotemporal field perturbations. Magn Reson Med. 2011;65:1690-1701. doi:10.1002/mrm.22767
  2. Wilm BJ, Barmet C, Pruessmann KP. Fast higher-order MR image reconstruction using singular-vector separation. IEEE Trans Med Imaging. 2012;31:1396-1403. doi:10.1109/TMI.2012.2190991 Erratum: IEEE Trans Med Imaging. 2012;31(9):1833, listed in the PubMed record.
  3. Lee NG, Ramasawmy R, Lim Y, Campbell-Washburn AE, Nayak KS. MaxGIRF: Image reconstruction incorporating concomitant field and gradient impulse response function effects. Magn Reson Med. 2022;88:691-710. doi:10.1002/mrm.29232
  4. Halko N, Martinsson PG, Tropp JA. Finding structure with randomness: Probabilistic algorithms for constructing approximate matrix decompositions. SIAM Rev. 2011;53:217-288. doi:10.1137/090771806
  5. Eckart C, Young G. The approximation of one matrix by another of lower rank. Psychometrika. 1936;1:211-218. doi:10.1007/BF02288367
  6. Barmet C, De Zanche N, Pruessmann KP. Spatiotemporal magnetic field monitoring for MR. Magn Reson Med. 2008;60:187-197. doi:10.1002/mrm.21603
  7. Vannesjo SJ, Haeberlin M, Kasper L, et al. Gradient system characterization by impulse response measurements with a dynamic field camera. Magn Reson Med. 2013;69:583-593. doi:10.1002/mrm.24263
  8. Dubovan PI, Baron CA. Model-based determination of the synchronization delay between MRI and trajectory data. Magn Reson Med. 2023;89:721-728. doi:10.1002/mrm.29460
  9. Robison RK, Devaraj A, Pipe JG. Fast, simple gradient delay estimation for spiral MRI. Magn Reson Med. 2010;63:1683-1690. doi:10.1002/mrm.22327
  10. Rosenzweig S, Holme HCM, Uecker M. Simple auto-calibrated gradient delay estimation from few spokes using Radial Intersections (RING). Magn Reson Med. 2019;81:1898-1906. doi:10.1002/mrm.27506
  11. Ianni JD, Grissom WA. Trajectory auto-corrected image reconstruction. Magn Reson Med. 2016;76:757-768. doi:10.1002/mrm.25916
  12. Huang F, Vijayakumar S, Li Y, Hertel S, Duensing GR. A software channel compression technique for faster reconstruction with many channels. Magn Reson Imaging. 2008;26:133-141. doi:10.1016/j.mri.2007.04.010
  13. Buehrer M, Pruessmann KP, Boesiger P, Kozerke S. Array compression for MRI with large coil arrays. Magn Reson Med. 2007;57:1131-1139. doi:10.1002/mrm.21237
  14. Kellman P, McVeigh ER. Image reconstruction in SNR units: A general method for SNR measurement. Magn Reson Med. 2005;54:1439-1447. doi:10.1002/mrm.20713 Erratum: Magn Reson Med. 2007;58(1):211-212. doi:10.1002/mrm.21261.
  15. Zhang T, Pauly JM, Vasanawala SS, Lustig M. Coil compression for accelerated imaging with Cartesian sampling. Magn Reson Med. 2013;69:571-582. doi:10.1002/mrm.24267
  16. Drmač Z, Gugercin S. A new selection operator for the discrete empirical interpolation method—Improved a priori error bound and extensions. SIAM J Sci Comput. 2016;38:A631-A648. doi:10.1137/15M1019271
  17. Peherstorfer B, Drmač Z, Gugercin S. Stability of discrete empirical interpolation and gappy proper orthogonal decomposition with randomized and deterministic sampling points. SIAM J Sci Comput. 2020;42:A2837-A2864. doi:10.1137/19M1307391
  18. Compton R, Osher S, Bouchard LS. Hybrid regularization for MRI reconstruction with static field inhomogeneity correction. Inverse Probl Imaging. 2013;7:1215-1233. doi:10.3934/ipi.2013.7.1215
  19. Lee NG, Cui SX, Nayak KS. Cartesian MaxGIRF: Model-based EPI reconstruction incorporating gradient nonlinearity and concomitant field effects. Magn Reson Med. 2026;95:1044-1067. First published online 2025. doi:10.1002/mrm.70113
  20. Tian R, Scheffler K. Group-Patch Joint Compression: Compressing dynamic B0 and static RF spatial modulations across k-space subregion groups for highly accelerated MRI. Magn Reson Med. 2026;96:2106-2126. doi:10.1002/mrm.70439
  21. Yu W, Gu Y, Li Y. Efficient randomized algorithms for the fixed-precision low-rank matrix approximation. SIAM J Matrix Anal Appl. 2018;39:1339-1359. doi:10.1137/17M1141977
  22. Demmel J, Grigori L, Hoemmen M, Langou J. Communication-optimal parallel and sequential QR and LU factorizations. SIAM J Sci Comput. 2012;34:A206-A239. doi:10.1137/080731992
  23. Himpe C, Leibner T, Rave S. Hierarchical approximate proper orthogonal decomposition. SIAM J Sci Comput. 2018;40:A3267-A3292. doi:10.1137/16M1085413
  24. Bianchi S, Pruessmann KP. A GPU-enhanced workflow for non-Fourier SENSE reconstruction. arXiv [preprint]. 2026;2604.09233v1. Submitted April 10, 2026. doi:10.48550/arXiv.2604.09233. Implementation section.
  25. Sirovich L. Turbulence and the dynamics of coherent structures. Part I: Coherent structures. Q Appl Math. 1987;45:561-571. doi:10.1090/qam/910462
  26. Everson R, Sirovich L. Karhunen-Loève procedure for gappy data. J Opt Soc Am A. 1995;12:1657-1664. doi:10.1364/JOSAA.12.001657. Author manuscript.
  27. Gonzalez TF. Clustering to minimize the maximum intercluster distance. Theor Comput Sci. 1985;38:293-306. doi:10.1016/0304-3975(85)90224-5
  28. Mirsky L. Symmetric gauge functions and unitarily invariant norms. Q J Math. 1960;11:50-59. doi:10.1093/qmath/11.1.50
  29. Maurer A, Pontil M. Empirical Bernstein bounds and sample variance penalization. Proceedings of the 22nd Annual Conference on Learning Theory (COLT). 2009. doi:10.48550/arXiv.0907.3740. Theorem 4 gives the fixed-function bounded-loss inequality discussed here.
  30. Sutton BP, Noll DC, Fessler JA. Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities. IEEE Trans Med Imaging. 2003;22:178-188. doi:10.1109/TMI.2002.808360

HighOrderMRI.jl documentation · stable · v0.1.2 · code 9af532a · docs 9af532a